  1. Place “Indicol” dial indicator holder on spindle nose
    • Place “Indicol” dial indicator holder on spindle nose

    • Place spindle in neutral gear.

    • Set indicator to swing a 9” circle (Full Y table width or tram ring diameter)

    • Set X axis first

    • Set a zero position in the X axis

    • Swing indicator 180 degrees in the X axis, note difference on indicator

    • Loosen the four ¾” bolts, and snug them

    • Using geared worm shaft, adjust as necessary

    • Re-torque the four bolts to 50 ft lbs

    • Repeat for the Y axis

    • (Note: the table is designed to be approximately .0005” high the front)

    • Loosen and snug three ¾” bolts

    • Using geared worm shaft adjust to .0005” high in front, zero in rear

    • Re-torque bolts to 50 ft. lbs.